logo100.png

camera.jpg

Testing Center 

The SKB Testing Center consists of Mechanical and Climate Testing Department and Electric and Vibroacoustic Testing Department, which provide full testing range of electric motors, electric generators and aggregated devices:  

- Vibroacoustic and Electric Testing   

• Acceptance, periodic, standard electric and thermal testing of electric motors and generators, electromechanical devices with electric motors and generators of max. 100 kW power and 400 Hz frequency.

• Aerodynamic testing of electromechanical devices with max. 100 kW power and 400 Hz frequency.

• Safety testing of household and similar electric devices.

• Noise testing and research of electric motors and electromechanical devices with max. 100 kW power and 400 Hz frequency.

• Vibration testing and research of electric motors and electromechanical devices with max. 100 kW power and 400 Hz frequency.

- Mechanical Testing

Sinusoidal vibration testing of the object with weight up to 200 kg:stend.PNG

• vibration range — 5-35 Hz

• vibration amplitude — max. 5 mm

• maximum acceleration — 5 g

Sinusoidal vibration testing of the object with weight up to 60 kg:

• vibration range — 10-1000 Hz

• vibration amplitude — max. 3 mm

• maximum acceleration — 10 g

Single and repeated impact testing: 

• tested object weight — max. 200 kg

• maximum acceleration — 150 g

• pulse duration — max. 20 ms

• pulse repetition frequency — max. 120 strokes per min.

- Climate Testing  

High and low ambient temperature testing: 

• chamber operating volume — 2.0 m3

• temperature range — from –60 to +100°С

• tested object weight — max. 200 kg

• tested object dimensions — 750 х 750 х 750 mm

Air humidity testing: 

• chamber operating volume — 1.0 m3

• operating temperature range — from +20 to +100°С

• relative humidity — 98 ± 2 %

• tested object weight — max. 200 kg

• tested object dimensions — 600 х 600 х 600 mm

Insulating and mechanical testing of:

• copper circular enamelled wires with diameter of 0.28-1.60 mm

• copper winding wires with fiber glass and polyester glass insulation and diameter of 0.315-1.5 mm

• film and film-containing materials.